- Atwood 7916-ii Tune-Up Kit. Atwood Furnace Series 7916-II Users Manual. Atwood Hydro Flame 7916-ii Technical Installation Manual MPD 32072. HydroFlame Furnace Exploded Views And Parts List. Tune-Up Kit #1 Obsolete / No Longer Available: Burner Assembly 30268. Single Sense Electrode 37517 (One Wire Goes To Electrode).
- Welcome to my latest RV trouble. In this RoamTownGirl series I will be repairing and fixing all the things that go wrong in my older RV, Scout.
This is a mechanical thermostat that's compatible with Atwood's Forced Air Propane Furnaces. This T-stat is heat only. 4 Reviews; 4 Reviews. 5 Atwood 32300 furnace thermostat. Posted by Robert Russell on Feb 14th 2021.
Download Installation and operation manual of Atwood HYDRO FLAME 2H2C Thermostat for Free or View it Online on All-Guides.com.
Brand: Atwood
Category: Thermostat
Type: Installation and operation manual for Atwood HYDRO FLAME 2H2C
Pages: 1 (0.11 Mb)
ENGLISH, FRANCAIS(et Canada)•Installation •Operation
LITERATURENUMBER
hydro flame
Model 2H2C
Digital Thermostat
9
12VDC
3
2
USED
4
COM
5
COM-
6
HI
7
LOW
8
FURNACE
(OFF) OFF
M
System Switch
Set
Set
Operating Voltage ......................9VDC to 18VDC
................................100mA
..................-40F to +185F
..............+55F to +90F
..+35F to +99F
................................+/- 1F
SCROLL ORDER OF
OPERATION
Scroll Order of Displayed Modes
•
AUFurnace automatically switches between high and low BTU valve and high
and low speed fan when cycling to satisfy set point.
Atwood Hydro Flame Thermostat Manual
HIFurnace high BTU valve and high speed furnace fan cycle to satisfy set point.
LOFurnace low BTU valve and low speed furnace fan cycle to satisfy set point.
HFFurnace fan runs at high speed to circulate air. Air conditioner fan does not run.
LFFurnace fan runs at low speed to circulate air. Air conditioner fan does not run.
Scroll Order of Displayed Modes
•
Air conditioner automatically switches compressor and high and low speed fan when
•
HIAir conditioner compressor and high speed fan operate to satisfy set point.
LOAir conditioner compressor and low speed fan operate to satisfy set point.
HFAir conditioner fan runs at high speed to circulate air. Furnace fan does not run.
LFAir conditioner fan runs at low speed to circulate air. Furnace fan does not run.
Scroll Order of Displayed Modes
•
HIAir conditioner fan and furnace fan run at high speed to circulate air.
LOAir conditioner fan and furnace fan run at low speed to circulate air.
Scroll Order of Displayed Modes
•
THERMOSTATINSTALLATION
Thermostat is very sensitive. HANDLEWITHCAREATALLTIMES.
Locate thermostat 48˝ to 54˝ above floor on an INTERIORwall.
Pick a dry area where air circulation is good. EXTERIORwall
location must have a 3/4˝ spacer between thermostat and
1. Be sure all electrical power has been disconnected from
the air conditioner, furnace and the power supply.
2. Do not install the thermostat where there are unusual
heating conditions: such as direct sunlight, heat produc-
ing appliances (television, radio, wall lamp, etc.)
3.
Atwood Hydro Flame Thermostat 38453 Manual
ATTACHINGTHEWALLTHERMOSTAT.Separate the thermostat
body from the sub-base by gently squeezing the top and
bottom. Pull wires through access hole in base plate.
Attach thermostat sub-base to the wall at the desired
mounting location. Mount the sub-base to the wall before
THISTHERMOSTATHASBEENDESIGNEDTOOPERATESTANDARDAIRCONDITIONINGUNITSINCONJUNCTIONWITHANEXCALIBUR2-STAGEFURNACE.
Note: Move jumper to
Atwood Hydro Flame Thermostat Troubleshooting
Unit. Discard jumper for
®